Emergency Electricity

Switches, routers and expensive servers need constant and protective feeding during electricity fluctuation or sudden disconnection and connection. In addition to the mentioned problem, by using UPS, we can continue working with equipment for a time during disconnection. These systems have to types; on line type for highly sensitive set as medical equipment of operating-room in hospitals, off line type for less sensitive set as computer. The online one always converts the direct current of batteries into 220 volt alternating current. But in the offline type, it takes two milliseconds during power cut so that the converter converts battery voltage into 220 volt alternating one. Different powers generate 400 volt ampere to several kilo volt amperes. UPS choice needs the calculation of consumption power and required electrification time.

 

 1) Some points must be taken into consideration in UPS choosing:

●The specification must be to the technical specifications' extent and answerable to the UPS testing stages.
●The Supplier Company must have technical educated agents in the cities which the UPS is installed.
●The Supplier Company must have MANUAL SERVICE so that if the UPS needs repairing, it is done as the special technical specifications.
●At least, one year warranty.
●The batteries must be able to supply the required time of the user for BACK UP.
●The server's UPSs must have the power of software service presentation on the used network's software in user set.

2) Physical specification and montage approach must be as following:
●UPS must take a small volume so that the maximum 5KVA dimension with batteries, takes less than 70×70×70 cm.
●The boards must be designed and constructed as module and separately so that in service and support stages, the different parts of UPSs have not any effect on each other and also the reparation and support's expense is decreased. By this approach, the reparation and support operation is done more quickly.
●The power units (transistors) must be insulated physically against wave's control and generation units. This case prevents from the entrance of sucked up dust of fan into the sensitive parts.
●The radiator of the transistors must have current channel, fan and heat sing, and the fan must be located in front of the current channel. This set must be insulated against other section of UPS. This mode is the best one for cooling the transistors and preventing the entrance of the fan's dust into the other sections.
●Transistors of the internal UPSs must be of new and powerful MOSFET types. The usage of BIPOLARs in UPS that were consumed in the last decade and have low output is not recommended.
●It is recommended to use vocal and light alarms on the different boards of UPS, to make easy the service, reparation and support process. Their instruction is explained in the directory.
●The UPS's box has the required firmness, the rivets or bolts are not used for connection.
●The internal units of the box are galvanized against humidity.
●It is better that the frame of the floor and back panel is galvanized to prevent from oxidation.
●It is better to use a metallic frame in the floor for strengthening, in addition to the usage of suitable iron for heavy transistor installation, to prevent damage during transportation.
 

3) The tests which UPS must answer:

●Transfer time in UPSs, sinus or sinoid, in conformity to the 446-IEEE standard must be less than one quarter of the city current cycle. It is tested by STORGE-SCOPE.
●THD of the linear load must be less than 3% in sinus UPS. (The instrument of the parameter must be presented by the manufacturer)
●THD of the nonlinear load in sinus UPS is less than 5%.
●The power of the sine wave UPS is unchangeable throughout the range.
●During the work of UPS, it must be protected when the plug is connected to the socket (positive feedback).
●The efficiency of the sinus UPS is more than 85%.
●The output regulation must be within the limit of less than 2/5%.
●The resonance UPS, in addition to the problem of nonconformity with sine wave, has high temperature, noise and etc problem. So, it is better not to use this technique in UPS construction.
●It is better that the UPS has a stabilizer so that keep the output rationally stable during the fluctuations of the current, without usage of battery.
●Required protection:
1. Short circuit output protection.
2. Inverted batteries' connection protection.
3. Overload and related alarm protection.
4. Over charge and discharge protection.
5. Spike protection.
6. Over voltage and under voltage protection.
7. Output over voltage protection.
8. Battery over voltage connection to the input and alarm activate protection. The system would not damage if more batteries are connected to the UPS input.
9. Input's fuse protection with standard and automatic fuses.
10. The temperature of 0 to 40 degrees centigrade at work.
11. 1%+ 50HZ output frequency.

●Some points about calculation of full power UPS battery

By considering the several and more than an hour current disconnection, it is required that UPS batteries can present service for more than an hour. A 5000VA UPS, other than more than an hour service, must have the frequency and heating capability.
The AH for a 5000VA UPS with DC voltage of 48 input is calculated as followed:
105 AH= 5000watt
So, the maximum which is required for the usage of 48 model battery is 105 AH.
 

Considerable points about batteries:

Batteries are divided to two types; Peculiar to UPS and Start model

 

Disadvantages of Start batteries:

1. They must always be in move and they would face problem in the stable situation.
2. They have been constructed for the short term starts; they are damaged if used for long term by UPS.
3. They must be charged by dynamo, after start current supply.
 

Advantages of the Peculiar to UPS batteries:

They are designed for high current and long term usage, peculiar to UPS. Their installation in one location would not make any problem for their active composition. By considering the used quality and technology in their construction, repeated charge and discharge would make no problem.

 

Suitable condition for Ups and related batteries installation:

Since UPS has the POWER equipment and connects the emergency electricity of one or some sensitive computer, it is required to keep in desirable condition.

 

Installation location:

●By considering the temperature, it must be in the range of 10_35. (It has more importance for the battery installation location rather than UPS.)
●The temperature must be less than 95%.
●The installation location must not have any vibration.
●It is better to use fan for suction of the environment heat that is produced by UPS performance.
●As far as possible, the UPS must be in a place where no rain, water or etc (in the kitchen) is spilled on it.
●By considering the sensitiveness of the electronic parts, avoid putting the UPS before dust.
●By considering the UPS alarm, Ups must be located in a place where the vocal and light alarms are seen easily. Avoid seriously from putting in the reservoir.
●By considering the sensitive protection of the UPS, it is required that a suitable card is connected to it, for current supply.
●By considering the possibility of usage of the UPS software capabilities, it is better that the maximum distance between UPS and related SERVER be as the 232RS standard. It means less than 5 meters.
With help of Double Conversion design, the output current will be full sine current that is regulated completely in respect of voltage and frequency and its noise has been decreased to the desirable level.
 

Usage of 32 byte Motorla central processor:

By usage of 32 byte Motorla microprocessors and quick and firm approaches of processing, these UPSs can entirely control the internal and external activities of the system quickly and precisely, and also they can make assurance of the output's safeness.

Protective Circuits in P.I.C UPSs:

Protection against: inverted connection of battery, overload, decrease and increase of output voltage, short circuit connection, decrease of battery voltage, thunder, current voltage and frequency changes, increase of internal temperature of the system and protection of telephone, fax, modem and DATA against noise.

 ● Wide acceptable Input Range without usage of battery
A wide range of AC voltage is accepted in this system. So the consumption rate of reserved energy is decreased in battery. It has an important role in continuous disconnection of current and increases the longevity of battery.
By using this circuit, the charge and discharge system is controlled precisely and the longevity of battery is guaranteed.
●Equipped with Self Test and Self Defect SystemIn this situation, the system tests the input, output, battery and bypass automatically and if any problem occurs, it announce that.
●High tolerance against overloadThis system can tolerate the overload to 105% during work and to 150% during usage of current or battery.
●Output Trans Isolation (elective)
●LCD Monitor
●Ability of Power Factor Correction (P.F.C)
●Ability to use internal battery for 1, 2 and 3 KV-AMP powers
●Ability to use external battery with long backup charge to 10 AMP for 1, 2, 3 and 6 KV-AMP powers
●Ability to work with diesel generator current
●Battery charging when the system is turned off
●Online-Double Conversion designing which can resolve all the current problems
●Short time for reparation, by considering the modern design
●Having real warranty and high speed and quality for service supply and support
●Connection with computer
 

UPSs are connected to the computers differently:

●232RS DOORWAY

UPS can easily connect to the computer and control its performance by using cable and 232RS protocol and related software.

 

●SNMP CARD

 This card converts the RS232 relational signal into the perceivable signal for computer networks. By its usage, the possibility of complete management and UPS control via network (even internet) is provided.

 

●SOFTWARE

The UPSILON 2000 software, has the ability of conformity and compatibility with operating system of Windows 95/98/2000/ME/NT/XP, Unix, Novell, Linux and etc, can show parameters as voltage, frequency, load rate, battery situation, errors record, UPS situation report and etc. and when the battery reserve is over, it saves the computer's files and do the Auto Shut Down program.

 

●Some other advantages of relational tools are:

 

*Saving the information and turning off the systems when the UPS battery is completely over.
*Contact people via mobile, telephone, pager, email and etc. in time of need.
*Input and output voltage and frequency presentation, battery and load situation
*UPS performance report presentation, record and save, type and precious time of error.
*Ability to programming for UPS turns on and off.And etc.

 

Output UPS


●Entirely sine wave shape; protector of sensitive systems against current problemsPower surge
●Over voltage (usually more than 110%) for some consecutive cycles, it is usually made by decreasing of load or finishing a big load.
●Over voltage; Over voltage for long period, this case is usually related to the distribution network and can damage different parts of the systems.
●Spike/ Transient; Quick and sudden voltage fluctuations, that usually last about one or two cycle. These fluctuations have effect on processors, information exchange and etc.
●Frequency Variation; Current changes, this case is one of the problems of the supporter sources like generators and can makes difficulty in systems performance.

●Power Failure; It is complete disconnection of the current for more than half of the cycle. Disconnection may cause lose of the information and damage of the system's hardware.
●Power Sag; Decrease of the voltage for some consecutive cycles. It arises from the start to work of a big load with high current like ventilation or electrical motors.
●Under voltage; Decrease of the voltage for long time, this problem is concerned to the distribution network and can make many difficulties for the system.
●Noise; It is usually produced by power supplier or radio and magnetic waves. Noise causes false transfer of information and makes difficulty in system's performance.
●Harmonics; An extra wave with small range, its frequency is a multiple of the original wave's frequency. These harmonics cause errors happening in the network and increasing of the systems' temperature.
 