Network card
Network card is used for connection to local
network at 10,100 and 1000 meagabite per second ,
with ports RJ-45 And BNC for the networks on the
bases of cupric cable and with port optic fiber for
connection to optic fiber . Variouse factories
produce these kind of cards with different prices
and different possibilities of usage .
HUB network switch
The heart of any network is formed on the bases of
Star HUB Switch . The second layer switches are
produced with 5 , 8 , 16 , 24 and sometimes with 36
, 48 port . Nowadays their speed is usually 10,100
and 1000 megabite per second . The switches containe
ports Rj-45 or optic fiber or a compound of both of
them .There are two kinds of HUB switches :
Rack mounted type .
On the desk type .
The on the desk one , having ability of rack mount
for installation standard racks of 19 inches is
available . Ecceleration of switching is the most
important specification of a switch . According to
the needs and designation of the network , different
switches with variouse ports are soled at the market
. A few number of companies provide replaced
switches during the guarantee duration , so , that
you can always erect your network . The guarantee of
switches are usually about one to three years of
duration .
Management Switches
To control and protection of large networks , or the
networks swhich need to have much wider and
controlled strip , usage of management switches are
needed . With these kind of awitches it can be
arranged variouse jobs such as the width of bands ,
figurative networks , controlling and reports of
network traffic and … etc . The specifics almost
shared all of them are : being rack mount , metal
covered , 24 ports and above , the possibility of
additional much many kind of modules for variouse
application , output serial of ports for direct
managing , the possible managing within the web ,
having software management , internal powers , spare
powers , and the much more high prices compared with
the crrent switches the much more high prices
compared with the current switches can be mentioned
. While using such of very expensive switches , you
must pay most necessary attentions to the
electricity , and earthy currents , and any
estimations in your network system must be taken
into carefully consideration . The eccelerating of
internal switch , and also the capacity of
transmission data at a time unit , are the important
specification of such high prices determination .
Some of such switches have also the functional
possibility within three or above networks . For
connection such switches to each other , the special
central switches , called (core) with high power of
transmission are used .
Module Switch
Modules are the parts of hardware , that are
connected to the main hardware , and adds some
possibilities of the network needs . The switches
that have input for installation of modules are
called modular switches . Each family of switches
can have from one module to much many of them , and
different factories supply such modules with
different application for their switches . Each
module can have many ports of the same or different
. The latest modules are SFB or Mini GIBIC that
provide various types of GIGA bite ports on optic
fiber and cupric cables . Modular switch gives the
possibility to ntwork designer so can have much many
of media types side by side . Choosing module needs
to necessary information about the kinds of media
and the distances and speeds which provides . The
modules of a switch family have very many different
prices .
KVM Switch
This apparatus provides the possible control of
2,4,8 or 16 set of computers through a monitor and a
mouse and one keyboard . It is usually used in rack
o control many of servers and so , to reduce the
costs . Some kinds of them connected to each other
can support up to 256 computers and more as well .
One of the plenty usage of it , is related to
assemblers and the menders of computer .
Print Server
You can provide one or three set of printer by
print server , to all of the network users at the
same time . Print server is directly connected to
the network switch . Its advantage to "print
sharing" is that, not getting the power of server or
other apparatus to use , is not viroused , dosen,t
hang and the user mistake dosen,t cause disabling
the printing services of other users . This is one
of he necessary apparatuse for the large networks .
Internet Server
By directly connection of this apparatus to the
network switch all of the users , "provided
authority" , can get the use of internet server .
You can connect with two servers of internet by one
or two external modems with tow line of telephones .
The other possibility advantages of the apparatus
are as follows .
Mail , internet , DHCP , account server .
Arrangements are done through explorer .
Internet network webcam .
While you are connecting these webcam to the network
switch , all of the users , "prvded authority" , can
see the picture that these webcams send . There is
the possibility of controling sixteen webcams at
same time , its lenze is adjustable and some types
of them , function sound recording or movement
actions and zooming as well , its speed is up to 30
frame each second , and the maximum preciseness is
640×480 .
Router
The networks are connected to each other by
Routers .
The entire word is connected by Routers to each
other , and so the internet network has been formed
. These apparatus have complicated functions , and
they need to soft ware arrangements . Some of them
have the ability of module installation and various
possibilities by these modules are added to them.
The best router selers in iran,s market are made of
sisco systems company . Related to the power of
management and transmission of data and
possibilities , they have different prices . Each
router at least has a LAN port for connection to
local network , and has one WAN port far connection
to a for away network.
Module Router
A piece of hardware which is placed inside the
Router , and adds a particular possibility to it .
Any family of Router , has its own speciality that
is designed for it . For example NM16AM Module 16
modem analog adds to sisco Routers . In appropariate
to the type of module the prices are varied from 50
several thousand dollars .
USB netrwork card
By using this small connecvtor the computer through
USB port will be connected to the network . This
apparatus has function that our computer has no any
network card . There are kinds of such USB 2.0 and
USB 1.1 at the market .
Media converter of optic fiber
Media converter of optic fiber are used for
transmission of data from cables of optic fiber.They
have a speed of 100 megabite and 1000 megabite , and
according to the distance and speed are provided
with output types of SX,FX and LX.They uaually have
a port for connection to the network cable and one
port for connection to optic fiber . The type of the
optic fiber port should be appropariate with
connectors chosen and used in the network . For
functioning , they need to a feeding source . If we
want to connect a switch that has no optic fiber
port , to the optic fiber we shall use media
converter .
Multi port
If there are not enough number of ports in a
computer set or server we can use multi port to
increase these ports.This multiports are in two
types , internal and external , and there are 4 port
, 8 port and increasable 8port up To 32.The most
functional of that in ICT relates to connection of
several modem sets to a server is a starting run of
a small ISP or an internet network . But in industry
there are plenty of applications such as ; CNC
control apparatus and other ipparatuses that serials
of standard protocols such as RS232 work.ON any
computer set it can be created up to 128 serial
ports by these molti ports .The transmission speed
of data is the important factor of multi port price.
VolP Gateway
Gateway can supply the voice transmission
services phone on data lines. These are of two kinds
FXS Port for data transmission internally and FXO
for connection to telephone or the reciver of
ordinary phones.while the data transmission online
between two locations is running without any
inconvenience we can transmit the phone lines by
using the transmission data of these lines as well .
So we can transmit a phone line from Tenran to
Mashhad.The usage of this method;as internet cards
are available at some market centers.
IP Phone
These kind of phone receivers , are directly
connected to switch network,and a purticular IP is
difined for them,and can under the network , operate
as an ordinary phone . It is estimated nowadays
Analog phones will be replacsd by IP at the very
future of time .
Wireless net work card
To start running a wireless network , it is just
enough to fix a wireless card network on each
computer . More so , there is no need to install any
other apparatus . These cards work with ll,22,54,108
megabites speed and appropariately to environment
conditions their speed of transmission vary . In
indoors up to 100 meter and in outdoors up to 300
meter is its range of non obstacles . By aerial
changing its range can be strengthened .
Access Point
Access point connects a wireless network to a local
one . It has a Rj-45 port to be connected to the
network switch , and an aerial to be connected to
the wireless network . Some of the kinds are bridge
shaped , and can erect connections between two local
networks that are far from each other . In the case
of Repeater , the signal is repeated for long
distance .
Wireless Bridge
The bridges erect connection between the local
networks with wireless waves . These sorts of
bridges with different earils can support up to 50
kilometers of distance , as well . .Their functional
frequency is usually 2.4 or 5.8 giga hirts , which
are amateur frequencies and there is no need to have
the authority . It is designed to be installed
outdoors , and has the ability to funcyion in low
and high temperatures . The apparatus has been
designed water tight to protct it of any raining
water penetration . There are functional securities
for coding the information and protection of data on
the bridges . An apparatus , called , POE , is
supplied together with the apparatus , that the
electric current of low voltages through network
cables to this apparatus from inside the building is
carried on.These bridges together with gate ways are
combined and are used for transmission of phone
lines to remote or wanting earias.
Indoors earials
If spreading power or Gain aerial network card
or your access point is not enough,you may use more
powerfull aerials . These aerials are in two kinds
of Omin with spreading angle of 180 degree and Flat
are supplied for spreading directions.
Omin aerials
Bar shapped aerials that have ability of spreading
waves directions of all angles . These aerials are
supplied with special tighteners for connection to
the base and lightning-rod protector transmission of
lightning and thunder electric power into the earth
. Also there are the possibility of fixing these
aerials on different kinds of stsndard outdoor
bridges , and with 8dbi UP to 15dbi are producted .
They have been covered with fiber glass .
Parabolic aerials
The directional aerials for transmission of waves to
long distances , as reticular in surface . They are
light and non wind barrier . In different powers of
24 dbi , 27 dbi and 30 dbi are supplied . For
transmission of communication lines these kind of
aerials are used .
Flat aerials
The surface of aerials are flat , and they are
made with different angles of spreading waves.
Together with special tighteners to be connected the
base and lightning –rod protector for electric power
coming from ligtning and thunder into the earth are
provided . There are also the possibility of
installment of aerils on different kinds of standard
bridge outdoor , and with 15 dbi up to 18 dbi power
are produced . Their surfaces are covered with fiber
glass .
Yagi aerials
Branched directional aerials , such as television
aerials , that are installed on the roof of buldings
. These aerials with special brackets to be
connected to the base , together with lightning –rod
protector for transmission of the electric power
from , lightning and thunder into the earth , are
provided . Also there are possibility of installment
of such aerials on the kinds of outdoor standard
bridges , and with powers of 18 dbi up to 20 dbi are
produced . Their surfaces are covered with fiber
glass to prevent any freezing and the aerials are
cylinder shapped .
Fax Internal Modem
Fax modem card PCI with 56 killo bite speed per
second . They usually have functions of V.92 and the
phone line is not engaged while internet connection
. As of their low prices , they are yhe best selling
modem kind at the , market . There are only in some
kinds of them that their system shows the number of
person who you are speaking to .
Fax Serial Modems
Fax modems with ability to the serial ports of
computer set . Although they are of good quality ,
but because of advancement in technology , more or
less they are becoming out of orders , and USB modem
fax are replaced . Their speed of 56 kbps and some
of them support the V.92 functions .
Fax Modems USB
The modem faxes which are very fast in speed and
complete while working with it , and so you can find
out and feel the different of them in relation to
other fax modems . They have the speed of 56 kbps
and possibility of V.92 supports . Some of them have
sonic output and whenever of installation to the
apparatus , any time is recognized and runed by
windows . Also there is no need to separte feeding
source , display lights , the condition and the
communication of the modem completely .
Digital webcam
Todays digital webcams are supplied carefully with 4
megapicksel and above . They have usually 8 or 16
mega bite memory and can save too many number of
pictures with variouse preciseness . Of course , by
memorial cards we can increase the capacity of the
momory . They are produced in two types , CMOS with
sensor and CCD sensor . The CCD sensor has a very
high quality . Also , the possibility of taking
films in limited case together with voice is added
to them . Some of them have the possible usage in
the case of webcam . They can have two kinds of zoom
digital and optical , that the zoom optical will
increase the price of the webcam. There are the
possibilties of file copy on these webcams for
transportation and transmission to other coputers .
It also has the television output . All of them have
coloured monitors to see the pictures , and it is
connected to the computer by USB port .
Webcam
If you have got a webcam , you can have a live
internet connection in your local network with
pictures . Chat programs such as yahoo messenger
erects the possibilities of pictural connection by
webcam . The 320 killo pisksell has better quality
and can send 30 frams of pictures per second .
Flash Disk
For purposes of transmission and transportation and
supports of your files , use the small and light and
pretty USB disks . The 2.0 USB kind has very much
high speed , and capacity in 128 , 256 and 512mega
bite and one giga bite are produced . In XP Windows
2000 there is no need to install driver . And while
the apparatus is on , it can be connected and
disconnect .
USB Lock
"USB lock" can lock a port of your hard , so
that the part of your hard disk can be seen,only
when the lock is connected to the set . Also it can
lock the apparatus to prevent from internet
connection,and,or start-runing system is locked. Its
size is small and portable even on your key bunch .
Anyone can have his own particular lock.
HUB USB
If you have too many USB devices and you haven’t
got enough USB Ports on your computer or if you wold
like a number of USB on your working desk for easy
reach,you can use USB-HUB These HUB are produced in
types of 4 port and 7 port and … ect.
USB LINK
By this link you can make connection between two
computers and transmit the files to one
another.There are two kinds of USB 1.1 and USB2.0 at
the market , and the USB2.0 has so much more speed
and is light,small and portable.
BOLETUS ADAPTOR
It is used for connection between computer and
devices that has the possibility of Boletus,such as
some of mobile receivers or some of printers.They
are supplied in three models,with ranges of 10,20
and 100 meters.The Boletus has a less width of strip
and it has been designed for computer connection
with round about devices and to remove the
connection cables . By these Adaptors we can erect a
wireless system with less width of strip.
MEMORY CARD
Nowadays MEMORY CARD are supplied with
capacities of 128,256,512 Megabite and one giga bite
.The memory cards are supplied in two kinds of SD
and MMC.Although SD is more expensive , but it has
more speed and less consumption costs ,
comperatively with MMC.
CAMERA TRIPOD
To take and have more clear pictures , usually
the camera is fixed of Tripods.These small camera
Tripods in standard case are fixed on digital
cameras . Also,while with the timer of camera you
want to take picture of your own , the tripod will
make the adjustment easy . These tripods are
portable and can be folded.
MINI KEY BOARD
Mini keyboards are the small ones , that are
fixed insid the Racks . So like as ordinary keyboard
they can,t be fixed on movable trays easyly.These
keboards give you the possibility that on one Rack
drawer,you may have mouse and keyboard side by side
all together with.
USB A-B CABLE
This kind of cable connection for connecting the
round about devices having USB port , such as ,
printer, scanner modem and ect , are used . lts
length is about 1.8 meter. A kind of the new latest
one containing ability of being folded automaticly ,
and is used for transportation together with lap-tap
in particular.
USB TORS-232 converter.
If you need the conneetion of devices with serial
port to USB port of your computer , you may get the
usage of this connection , that there are two kinds
of ports , serials of pistil and virility serials at
the market.
Splitters Monitor.
By this device you can transmit the output card
graphic to four monitores at the same time . In this
case all of the monitors display the same picture .
The most application of the device is in showing
shops and markets.
RJ-45 network connector
Connectors with 8 pins of network in topology
star are used for the connection of network cables
to the devices. Its good quality relates to the
metallic pins covers that has been plated on them .
The best cover is of 50 microns. These connectors by
special pressing devices are connected to the
network cables . The connction of such connectors to
the network cables must be done in accordance with
standard colour ranges . They are avlable in two
kinds of non coated and metal caoted FTP (for
installation of high noisy environment on coated
cables ).
Handy installtion of such connectors for important
networks are not recommended at all, and instead of
that the testing provided available pach cords of
factories must be used.
RJ-11 Telephone connector
Rj-11 connectors containe 4 or 6 metalic pins,that
are used more for telephone and communications . It
is also known as slip Panasonic at the market . The
cables used in this connectors are with flat four
branches , and for installdlion to flat cable . The
needs for pressing special devices are a must .
Cover Connector
The designed elastic cover for RJ-45 connector
plus making beauty the cable , it protect the
intermediary cable connect to the connector and
prevent any dust into the port as well.
Rj- s45 coupler
If there is a need to increase the length of network
cable,they shouldn’t be taken off the covers to
connect with eachother or soldering wires. For this
purpose the RJ-45 couplers that containe 2 ports of
pistils must be used.
Surface Mounting network socket.
The frame work of sucket surface mounted on the wall
are installed by particular double stick glue or by
the role plague screws , and you can fix various
models of kistons inside it. Some kinds of them have
shutters on the port , so prevent of any dust into
it.The single and double port models with various
qualities and different prices are supplied . By
lables sticked on them you may identify the nomber
of the socket in the network.
Face plate of network:
Face plate or socket plate internally worked in the
network must be installed on standard box . If you
have already put this box inside the wall,while
building,you can easyly install the standard face
plate on it . In the kinds of the flat and 45 degree
single port and double ports with different
quantities and various prices are supplied . You may
identify the nomber of the socket by the lables that
have been sticked on some kinds of them .
Kiston
Kiston is connected to the network cable and it
makes us a port pistil Rg-45 . Kiston is placed
inside the socket frome of the network or is placed
insid the patch panel modular . In completed
networks at the first end and bottom end of any
cable kistons are placed . They are supplied in two
kinds of uncoated and metal covered FTP (for
installation in high noise environments and on
coated cables ) . Kiston should be approparite and
chosen in accordance with the cable type.For
example, while we have the cat6 cable in the
network,we must use the kiston cat6.
Back box socket
Back box socket is installed for intallation of
network face plate inside the wall or on the
wall,and containe different depth that is choseh in
accordance with the need.
Patch panels of non-modural(loaded)
In wiring cable works built , the patch panels are
placed inside the racks , and all network cables are
connected to these patch panels . One end of all
wire cables of network are connected into the
network sockets and the other end are connected to
the patch panels . The foult finding is very easy on
such networks . Patch panels of non-modular are
produced in cat5e and cat6 types with ports 16 , 24
, 36 and 48 ports coloured and black with the angles
of 180 and 45 degrees . They are also available in
two kinds of non-protected and metal-protected of
FTP(for installation in environments with high noise
and on the coated cables ) . In general usage from
these patch panels for the transmission of data are
not recommended , and they are more appropariote for
the voice transmission . Also they don’t have
flexible ability in large networks , and will cause
limitation for the designer . Instead of that , it
is better to use the modular patch panels .
Modular patch panels
The modular patch panels have all advantages of
non-modular patch panels that already were mentioned
. Besides , we can have all the port type such as
UTP , STP , FTP and even we may have the kinds of
port optic fiber such as multi and single ports side
by side . If any port , caused any of problems ,
only the kiston will be changed and there is no need
to change the patch panel completely . Even , we can
have cat5e , cat6 and cat7 side by side . This
subject will reduce the cost of project and it takes
the least space inside the rack . These patch panels
are produced in types 12 , 16 , 24 , 32 , 36 and ect
. All in all , the installation of them are easier
and some kinds have support bar for neeting the
cables to be held complelelly all on the back side
of the patch panel .
Communication patch panel
Communication patch panels that are used mostly in
ISP containe 16 ports of Iranian made and 25 ports
of Tiwonies . Both of these patch panels allocate
the same space of a unit in the racks .
Cable Management
Holding cables or cable management is placed
between the panel and the network switch inside the
racks . Its function is to hold the patch cords
inside the rack . Cable management prevents of
falling patch cords on other equipments inside the
racks and we give them more good order and
arrangement . They are produced in two types of
hooked and caped models . Also , single and double
unit of its models are available , but the single
unit model is used more .
Support Bar
Support Bar is placed on the back side of patch
panel , and it makes it easy to hold and management
of cables on the back side of the patch panel . Some
of patch panels have their own support bar , and for
the other it can be prepared in separate . Since the
network cables are fastened by belt to support bar ,
so the possible cutting off from the patch panel is
reduced .
Cupric patch cord
Patch cord is used for connection between network
switch and patch panel , and connection between
computer (network card) and the network socket . The
patch cord is one of the most important part of the
network , that can effect on the efficiancy of the
network . The patch cords are made from the soft and
sprinkle cables . The known manufacturers do various
tests on patch cord after production , to make sure
of it to be standard . They are supplied in length
50cm and 1 , 2 , 3 , 5 , 10 , 15 meters of different
colours . They are made in two kinds PVC jacket and
LSZH , that the second one , is without Haloogen ,
and when firing doesn’t produce poisoned smoke .
Handy mode of such patch cords specially with wire
cable , are not recommended by no means . There are
four ranges of frequency respond for cupric patch
cords as cat5 , cat5e , cat6 and cat7 .
BNC connection
The BUS network are out of order , but , so as
some of our companies and factories are using the
old networks , so these kind of connections are
supplied at the market . The mentioned connections
are as BNC connector , T connector terminator or
flexed and Brale or 1 connector . The special press
equipment is needed for BNC connector .
4 Pairs network cable
The special cable for the star networks is a 100 ohm
4 pair cables , that each two pairs have been
towisted to each other. These cables usually are
produced in packages of 305 meters (1000 feet ) in
circled or inside the cartons. The network cable is
of most important part of the network , that the
installation cost is very high,we must pay high
attention when we choose these kinds of
cobles,because there are the forged and real ones in
apparent as the same as eachother at the market.To
distinguish the real and forged cables is
possible,only with very expensive tester devices of
such special purpose available.These cables are
supplied in current kinds cat5e , car6 , cat7 ,
without shield UTP , with foile Aluminum , FTP , and
with shield STP , and sometimes with foile and
shield SFTP , in various colours and two kinds of
jacket PVC , LSZH , that the second one has no
Halogen and dosent produce toxic smoke when firing .
The speed of two pairs twisted from the the cable of
different networks are as follows :
Cat6 = 250 mhz
Cat5e = 200 mhz , 350 mhz
Cat7 = 600 mhz
Coaxial network cable
Network cable 50 ohm containing shield and adapter ,
special of BUS networks , that rarely is used
nowadays .
Optic fiber
We use optic fiber when need to connect far away
distances or more width strip is needed. The best
transmission is optic fiber which has plenty
advantages . The optic fibers that are used in
network job should containe two lines or a
coefficient of two . The optic fibers in the forms
of jacket are divided in various types such as
anti-chewing , armored glassing , steel wire armored
and … ect . Also according to the usage location
they are divided into 3 groups such as indoor for
internal usag inside the room , indoor/outdoor usage
in building or plastic and matalic chanels , and
outdoors for direct usage in free air space . The
optic fiber must be chosen appropariaty with the
needs of the network . There are two groups of optic
fiber such as multi mode and single mode . Multi
mode itself is divided into two parties , one with
two nucleus of 52.5 micron , and the other one 50
micron . The multi mode fiber can respond up to 2
killometer in 100 megabite speed . But in giga bite
speed multimode (9 micron) according to the
equipments used they can be supported up to 7o
kilometers . Instsllstion of optic – fiber
connections need to special facilities that are very
expensive .
Optic fiber patch cord
Patch cord are used for the connection between optic
fiber patch panel and the network switch . These
patch cords must be chosen appropariate with optic
fiber . For example single mode patch cord for
single mode fiber and multi mode patch cord for
multi fiber 50 for appropriate of its fiber and so
of patch cord fiber 62.5 micron . Patch cords have
different connectors , that have been installed on
them in the factory . Such as :Rj –MT , LC , SC , ST
, VF 45 , that in some patch cords connectors , of
one end of patch cord , is differ from the other end
, for various usages . such as patch cord SC to Lc
and … new fiber patch cord s containe high level of
flixiable ability and they are not easyly broken .
The length of these patch cords are usually 1 , 2 ,
3, 5 and 10 mater .
Optic fiber connectors
The optic fiber connector is installed on optic
fiber by very spscial equipments , and it gives us
the ability of data transmission . Some of the kinds
of these connectors are as follows : MT – Rj and LC
and SC and ST , VF-45 that are divided in two groups
of single and multi mode .
Optic fiber adaptor
Optic fiber adaptor is the medium between optic
fiber , that the connector is installed on it , and
the optic patch cord . This adaptor generally is
placed inside the patch panel of special fiber , and
there are variety of them appropariate with the kind
of connector in the form of 2 port (Duplex) or
single port (Simplex)
Optic fiber socket VF- 45
This is a velatively new invention of 3M company
, that made easiness in connections of optic fiber
and reduced the costs . The advantages of this
socket can be such as : easiness and the
installation speed , automatic shutter of socket and
connector , prevention of dust interance and
prevention of the Laser rays into the eye , the
possibility of installation beside of other cupric
kistons in patch panel or inside the face – plates ,
very appropariate cost , direct fiber connections to
eachother and the reduction of optic signal wastage
, can be mentioned . In this technology there is no
need of using the optic fiber adaptor . Even with
its special patch cords with ability of high
flixiable the optic fiber can be taken on user,s
desk , as the same as cupric cable . If using the
olden installation equipments , you may install
advanced sockets of VF 45 just by prepairing two
pieces of tools .
Optic fiber tools bag
Optic fiber tools bag is special for
instsllation of sockets VF – 45 . The price of such
tools in relation to the similar types are suitable
and containe complete equipments for optic fiber
sockets installation . Also there are training
inatallation CD film and directory .
Doubler port
If you have a one port network in a location ,
and you need another one port now , and there is no
way of possibility to cable wiring work againe , you
can get the use of dobler port . In this case it is
necessary to place two pieces of these doubler at
first end and bottom . end of the network cable .
This system has only the application on networks
with 10/100 Mega – bite .
Network pressing spanner
Network pressing spanner is specially for Rj – 45
connector , that containes wire cutter as well . In
two kinds as : with input connector by the side and
with input connector by the front part of the
spanner . The spanner with the front input is made
of AMP company , that has higher ability and price
in relation to the similar ones . If you are merely
doing the network and have no engagement with phone
connectors , these spanners are a good choice of
yours .
Network and telephone pressing spanner
The network and telephone pressing apanner are of 2
or 3 kinds . The first one input is special for Rj –
45 connectors , and the second one input is special
for Rj – 12 and Rj – 11 connectors . Some of the
kinds containe a third input for connectors more
small , special for phone receivers . In accordance
with the price , they have different abilities , and
this abilities are obvious , specially when too many
numbers of connectors are installed . Some of them
have automatic lock for closing spanner .
BNC pressing connector spanner
The BNC pressing connector spanners in type are
contained of 4 or 5 holes . They are supplied with
different abilities at the market . This kind of
spanners have automatic lock . Since the network
based on BUS have been out of order , so the
consumption of such spanners are of very little use
.
Punch spanner
This kind of spanner are used to punch the
network wires of communication , inside the
terminals , kistons and patch panel of non-modural .
The extra wire is cut by the spanner with the
pressing of the wire in its place accordingly . In
two kinds containig scissors that cutting off extra
wire by the spanner,s blade is done . Some of the
types have the pressur measurement screw , and some
have belt hook .
Cable striper of network
Striper (cable striper) the coated or as the
some as jacket cable is uncoated without any damage
to the wires inside the cable and easly separted ,
and it is one of the most necessary tools while
network installation . This tools have cutting
blades and the screw adjustment to adjust with
oppropriate cable for oppropriate dimension of the
cable .
Network tools bag
Network tools includes a nomber of tools for network
installation that are inside a set . In general the
tools inside these bags are such as : network
pressing spanner , cable striper , punching spanner
and the network tester . In relation to the price ,
the quqlity and the nomber of tools are varied .
Network Testers
Such testers are just used to make communication
test on the links of the local network . Some of the
types of such testers , beside testing the
connections of Rj-45 they can also chech up the BUS
netwoks , BNC connections , telephone , USB and PS/2
. Proportionately of quality function they are of
various prices . These testers are divided in two
basic parts , the testers and the remote testers ,
that the remote one is connected to bottom of the
cable and the testers is connected to the top end of
the cable and , so then do testing function . They
are fed by a 9 volt booklet battery as of the kinds
.
Some of them also have testing indicator on remote
ones. The indicators of such testers are in the form
of small shining ligtes LED with LCD monitors and
single coloured . While testing make sure that two
ends of the link is connected to the tester , and
not to be connected with the network card and or the
switch working , other wise it may cause problems
with the tester . A kinde of tester , lately
supplied at market can also show the length of under
testing cable on LCD monitoring indicator . Of
course , it is rather expensive than the other ones
. The model of testers that you see on the graph ,
can also check up the cable plan and indicate the
usuall kinde with the cross – bud type of the cable.
Professional Testers
Professional analysers of the network that the best
known of them is made of American Fluke can test all
of the specifications of the network cable , and for
each link the comparison with the standard ones ,
and they have the possible presentation of complete
reports on printer . They are cost about 8000
dollars each , and special high priced modular , for
tests of cupric patch cord and optic fiber links
will be added to the price . The employers of
important and large network , usually take delivery
of the finished project of contractors on the bases
of these analysers of network bed . It is obvious
that the contractors also announce the costs such
tests by such testers and receive these costs
separtately .
Cable numrator
Numrator is placed at the top and the bottom end
of the cable , and is usefull to prevent any vague
of the network supervisor and so the contractor
among too many of the cables . Each bunch contains
100 nomber of a kinde .
Cable pin
It is used to hold the cable inside the racks and
round about the user,s computer desk . They are
supplied in packages with 10 nombers of single ,
double , three and five of wires . It is installed
at the same place that already written on a label
sticked on the back of the pin .
Wall racks
The network standard equipments and the 19
inches rack mounted , can be placed inside the racks
. Wall racks are usually the units of 5 , 6 , 7 and
9 height . Unit is the single measurement of the
racks height , and is equal to 43.5 milometer . The
depth of the racks are also different . Their depth
can be 35 , 45 or 60 cm . Kid racks are used for
erection of small switches non-rack mounted on the
wall , and it,s depth is just 29 cm . 9 unit racks
are of many kinds and the panel side of some of them
is completely opened , and make the possible
reachment to rack from the side . Some have the
possible turning up to 100 degree and makes the
possible reachment to the rack back for the user .
The mentioned one is used for the switches that have
back modular . There are the possibility of
installation power units of 3 and ports and 12cm fan
on the wall racks .
Standing Racks
Standard standing racks are usually chosen to be
erected at the network center . In these racks ,
types of patch panel , switch , server , UPS and
other parts of the 19 inch racks mounted are
gathered alltogether for more easy management . They
have input of cable sorts at the top and the bottom
. Also they are opened from the four sides . The
height of such racks can be 16 , 21 , 28 , 36 , 40
and 44 units . They are produced with depth of 60 ,
80 and 100cm . They containe glass or mica framed
shutters . There are the possibility of intallation
one to four fans inside these racks , and
pre-assumptive they have only one fan . Horizontal
power modulars 8 port and 9 port are installed
inside these racks , and related to the rack height
vertical power modular can be installed as well .
Case Rack mounted
If you would like to have a special server
installed in rack you may select 3 or 4 units of
rack mounted cases . These cases are supplied with
400 watts powers . They containe locking shutter and
a filter which prevent dust inside the case , and
according to the design occupy less space of rack .
The installed fan inside this case is a 12×12 cm .
Fixed Rack Ranges
Ranges of fixed rack are divided into , one unit ,
two unit and flat . One unit ranges that are screwed
just on the front of rack are used to shine light on
equipments in it , and 2 unit ranges for holding
middle weight equipments , on the flat ranges of
fixed racks that four side of the rack are screwed ,
can lay weighty things such as : tower servers ,
monitores , UPS and … ect . The flat fixed ranges
inrelation to the type of rack containe depth of 60
, 80 and 100 centimeters .
Mobile Rack drawer
It is used to place keyboard and mouse inside
the rack . When open the rack,s shutter – comes
forwardly as drawer , and by putting the chair under
it , the network supervisor can get the use of it as
a desk . It is supplied with different drawes of 60
, 80 and 100 centimeter in accordance with the rack
type .
Monitor Frame
It is installed on the front of monitor on front
adaptor of rack , and harmonize the monitor with
other equipments inside the rack . It is appraviate
for monitors of 14 , 15 and 17 inches.
Digital thermometer
The thermometers freequentlly measure the
temperature of the rack , and indicate on their
digital display monitor . These thermometers
containe memory and if it reachs to the point that
the network supervisor determined , the fans start
running on . They are supplied in two kinds ,
Iranian made with 2 unit and foreign made with one
unit . They are usually installed right on the top
part of the rack .
Terminal Power
The equipment installed inside the rack need
electrical energy supply . The distribution of
electricity in rack , is done by terminal power and
the only electrical cable which gets out of rack is
the terminal power . These terminal powers are
cotained earth , that is better the earth wire must
be connected to the earth electric definitely . The
sockets used inside it are designed by frech lagrand
, they have acceptable quality . Kinds of 3 port and
4 port of it for wall racks , and it,s 8 port and 9
port are used for standing racks . The 8 port powers
have neonic key to turn on and off the rack,s fan .
There is the standing one with more ports , that can
be used in accordance with the rack height .
Blank panel
They are protective screens that are installed
to prevent of any touch to the sensitive equipments
inside the rack for more security . It is placed in
front of it . These blank panels are sipplied in
kinds of 1 , 2 , 3 , and 4 unit .
Fan Rack
The 12×12 centimeter fan that works with a
voltage of 220 and it is installed at the top end
part of the rack . There are two kinds of it at the
market : Bushed with lower quality and shorter
duration ,and with ballbearing more durable and high
price.The frame of these fans can be plastic or
metal.If you turn with hand the fan and so,runs for
a long time and then stop it is ball bearing
otherwise it is bushed fan.Also,if you press the
propeller of the ballbearing fan inwards it comes
back of elasticity movement.
Ratal lock
It is installed on the Rack,s shutter.For this
purpose the glass of rack must be cut in a special
shape . On the whole they are firm and of good
quality , and function much more better than the
ordinary glass ones .
Rack bolt and nut
These bolts and nuts and gaskets are of kinds of
galvanized plating , that the quality of the coating
with salt spray exams are controlled and tested ,
and there are a complete serial of 50 of such bolts
and nuts in each package . The mentioned nuts are
placed within the gap of Rack adaptors at desirable
place , and there is no need to hold it while we
screw the bolt in it . The white plastic gaskets
(washers) that are placed under the bolts , pays a
special beauty to the rack .
Rack Wheel
In each standing rack 4 wheels can be installed
for mobiles and more confortable movements .
Light panel
Florescent light that is installed at up end part of
the rack . While wenting off the electricity it
turns on by UPS and provides a greate help to the
network supervisor . This light panels occupy one
unit space and have the turning on and off key on
themselves .
Panel LCD
By this openable panel just with occuping two
unint space mouse , monitor and keyboard can be put
inside the rack . It contains platered hinge of
foreign made and on the whole prorides a very nice
and smart apparent to the raks . LCD monitor is made
of LG . In the case of using this panel there is no
need to have mobil tray.Another type of it includes
touch and pad mouse and keyboard.
Cable fastener
The plastic cable belt are used to bunch the
cables with each other or arrangement of the racks .
In general it has plenty advantages.Also they are
used to fasten the cables in channels and trackings.
The other kind of it is cloth made belt , (close –
fitting ) with the ability of fasten and open that
are used for larger bunch of wires.
Plastic channels
For installation of cables in the buildings , the
cables are to be passed through dockets and plastic
channels. In the case of doing the job , some ways
like path by these chanalls are made and so cables
from the ruck within these path up to the network
sockets are passed . These channels are provided
with width measurement of 2 , 2.5 , 3, 4, 5, 6 and 9
centimeters . All of them have a length of 2 meter ,
and each , proverblly is named " branch " .
Metallic tracking
Metallic tracking can be used when a standard
wiring cable system is under the construction .
These trackings are installed round about the rooms
with specific height from the ground or the floor ,
and through them various telephone lines , network
emergency electricity and local electricity are
transfered . The types of (face-plate) sockets can
be installed on these trackings . The other
qualities of such trackings are as : antinoise ,
easy installation and increasing easy movements of
the ports and tolerator of the much heavy weight of
the cables .
Emergency Electricity UPS
The high priced switches , Roters and Servers
while variation in electrical fluctuation or sudden
off and on need ptotected and stable feeding . By
using of (UPS) plus domination over mentioned
problems , when electricity goes off , we still can
continue up to some times , working with our
equipments . These apparatuses are used in two types
, online for much sensitive apparatus , such as the
medical equipment in surgical rooms , and offline
for less sensitive apparatus such as computer . In
online kinds of apparatus , always the activation of
direct voltage changes of battery to 220 volts is
done . But in offline one , when the local
electricity goes off it will take about 2 mili
second of time to replace and run the battery
voltage to 220 voltage of frequency . They are
produced with various powers of 400 volt amper up to
a few killo volt Ampers . To select UPS needs to
calculate – consumption capabilities and the time
needed for electricity current .
1) Some necessary notices appointed for choosing UPS
Respond UPS tests and specifications up to
possible technology .
The UPS supplier company should have technical
trained agencies in the cities of installation .
It is necessary for UPS supplier company for UPS
have already been provided , should have service
manual in the case of any repair and to mend the
subjects in accordance with technical specifics
rendering on UPS .
Guarantee duration is to be at least a year .
The kind of battery responding the duration of
back up needed for the consumer .
These UPS particular for server must have the
power of providing software services on networkes
softwares used in totall selection of the consumer .
2) The physical specification and the assembling
should be follows :
1- All UPS should have small volume , so as in
maximum dimension of 5 KVA together with batteries
occupy a volume of less than 70×70×70 cm .
2- In designation and making boards , the boards
must be in form of modular and separate . Because in
the cases of service and protection process , while
prevention of affects UPS variouse units on each
other,the mending and maintenance expens will be
reduced.By this method the speed of mending and
maintenance will be in creased.
3-Noticc that in UPS construction, power units are
isolated from control and wave forming production
and transistor power units.This subject cause
prevention of dust by fan vacumed on the various
sensitive units.
4-It is necessary the cooling system of transistory
part to be included air channel, fan and heat sing ,
and the fan placed in front of air channel and this
collection must be completely isolated from the
other parts of UPS .
This method of coolings the best method of cooling
transistors and prevents of any dust vacuumed by the
fan to the other parts .
5- It is necessary the transistors used in internal
UPS should be of the new and powerfull ones ( power
moseft ) , and using the kind of BIPOLAR that almost
were used in last decade having low efficiency in
UPS is not acceptable .
6- It is better to have sound and light alarms on
the various boards of UPS to easy serrice and
maintenance , and there should be the detailes of
using such alarms in the service note book .
7 – The mentioned UPS box should be firm enough and
it shouldn,t be connected to each other using with
rivetting or bolts and nuts .
8- The internal parts of the box should be
galwanized to be resistance against moisture .
9-It is better in construction of the frame the
floor and the back panel part at the apparatus being
galwanized to avoide of any rust .
10-It is better while transporting UPS , to avoid of
any damage of it , plus using an appropariate iron
under the apparatus since the transformator is very
heavy so by an ironic plate should be reinforced .
THE TESTS THAT UPS MUST RESPOND
1- Transfer time in kinds of UPS whether sinuos
or similar sinous must be in accordance with
standard LEEE-44b less than 1.4 cycle of local city
electricity,that this subject is tested by SCOPE .
STORGE.
2-In sinuous UPS , THD is to be on line bars less
than 3% (tools of such parameter should be provided
by the supplier )
3- In sinuous UPS THD on non-line bars is to be less
than 5%
4- The shape of the compeletlly sinuous must be
unchanged on all ranges of the UPS power .
5- UPS must be protected of connection input plug to
output socket (feed back positive ) in UPS normal
operation .
6- The efficiency sinuous models are to be more than
85% .
7- The output regulator is to be round about less
than 2.5% .
8- UPS ferresonance plus to problems about
unadjustment with the shape of wave sinuous have
objection of high temperature , noise and other
subjects . So it is better not to use such technic
in the UPS constructur .
9- It is better UPS to have stabilizer , so on the
condition of ups and fallings of local city
electricity without using output battery to
stabilize it to keep in an acceplable level .
10- Protection needs :
Protection to the short output connection .
Protection to reversed battery connection .
Protection of related extera alarm and loading .
Protection of over charged and over dischared
battery .
Protection to SPIKE
Protection to UPS and fallings of the local city
electricity over voltage , under voltage .
Protection over to over voltage in output , over
output voltage .
Protection over the connection battery voltage
overoutput , and activate the related alarm "Battery
overvoltage " by the existence of this protection in
the case of the connection to some more batteries to
the UPS input , this system will never have any
collision .
Fuse protection in input by standard fuses (and
automatic )
The temperature of the working condition 10 to 40
degree of centigrade .
Output frequency 50 Hz+ 1%
4- Notices in relation to calculation of battery in
UPS complete power .
Since it so happens that the current local
electricity goes off for many times and some times
longer than an hour , it is necessary to have UPS
batteries with power to provide electricity more
than an hour . For this purpose we need model 5000VA
for one UPS .Besides UPS must have the efficiency
and temperature power to provide such a long time
service.For presenting 5000VA on a UPS with DC
voltage the input of 48 volt Amper hour of battery
should be calculated as follows:
5000 = 105 AH
48
So , the minimum rate needed for providing 5000 vat
is the usage frome batteries of 105 amper hour .
The considerable points about the battries areas
fllows : batteries are divided into two groups ,
spical for UPS and starting models .
The objections to starting batteries
1- They should be always moving and in the case of
putting them in a stable place , then they are
involved problems .
2- They have been made for short starts and in the
conditions of using longly , they will be damged by
UPS .
3- After gathering the current start , they should
be charged by dynamo .
5- The Advantages of battery special for UPS
These batteries have been designed specially for UPS
for much current and using for a long time . Putting
such batteries in a certain place , dose,nt cause
any problem for their compounds of activities .
Discharges and again chargings repeatedly ,
considering the quality and technology of their
production will not occur any problem for the
batteries .
FAVOURABLE CONDITIONS OF UPS SETLLEMENT AND SO THE
BATTERIES
Since a UPS apparatus is of power equipment and
supplies the emergency electricity for one or a
nomber of computer systems , it is necessary to be
kept in good condition .
1- SETLLEMENT PLACE .
The temperature round about 10 to 35 degree , (of
course the heat temperature degree is more important
for the place of batteries rather than UPS ) .
Moistur of the place less than 95% .
The setllement place shouldn,t have any vibration
.
Evacuation of heat . Created while UPS operating ,
is better to be ventilated by fan .
At the most possibility UPS should be setlled in
such a place that there are not any possible raining
fall , kitchen water or any other things like that
may occur .
Since UPS containes very sensitive electronical
parts so , avoide to place it some where which are
in the direction of dusty ways .
As far as using UPS alarms , are included soundic
and lighting ones , then , it is better to put UPS
in such places that those alarms are easily reached
and visable , so , avoide seriously to put them in
warehouses or such places like that .
With due attention to the possible usage of UPS
software powers it is better that maximum distance
between UPS and server should be upto a limit that
the RS232 standard determines , that is to say ,
less than 5 meters .
With the help of double conversion design ,
existing electricity in the output of apparatus ,
will be a complete sinuous of electricity , so that
, due to voltage and frequency , completely arranged
, and its noise has been reduced to a desirable
limit .
Use of central processor Motorla of the 32 bite type
These UPS by using micro – processors of 32 bite of
Motorla – Company and the quick methods and
resistant process , renders the quick care full
control of all internal and external operations of
the apparatus and getting the secure results of
outputs .
Protective circle in UPS serials P.I.C
Protection against : reversed connection of battery
, over – loading , increasing and decreasing of
output voltage , short output connection , reduction
of battery voltage , thunderbolt , lightning and
thunder and variation in voltage and frequencies of
local city electricity , increasing the internal
heat of the apparatus and protection of telephone
lines , fax modem and data against noise .
WIDE DESIRABLE VOLTAGE LIMIT OF LICAL CITY
ELECTRICITY WITHOUT USAGE OF BATTERY .
In this system a wide limit of local electricity
voltage AC is accepted . There for , the energy
stored in the battery is reduced . This subject is
very important for going off the city electricity
continuously , and the age and duration of the
battery is increased as well .
Intelligent management battery system
By usage of this circle , charging and discharging
system is carefully controlled and the duration of
the battery is guarantied .
Equiped automatic system of test and fault finding
(self test)
In this case the apparatus automativaly tests the
input and output parts , battery and by pass , and
it will indicate in the case of any problem .
Tolerant while overloading
These apparatuses are able to tolerate over loading
UP to 150% for 10 seconds in the case of using the
local electricity or battery . These apparatuses
containe followungs :
Output isolated transistor (selected)
LCD display
Ability to adjust power input multiplier .
Ability usage of internal battery for powers 1 , 2
and 3 killo volt amper
Ability usage of external battery with long backup
charge , up to 10 amper for powers of 1 , 2 , 3 and
6 killo volt amper .
Ability of work with electricity of compressed
generator .
Chargeing the battery while the apparatus is off .
Design of online – double convdrsion that is able
to remove all problems occurred in local electricity
.
A very short time requirement for mending and
repaires with due attention to modern design .
Real guarantee and high speed quality in providing
the services and support .
Communication with computer
UPS are connected to computers with different varity
methods :
Rs 232
UPS using from cable and Rs232 protocal and the
related software can be easily connected to
computers and their operations are controlled .
SNMP card
This card changes the signal communication of Rs 232
to understanding signal for computer networks , and
by using it , complete possible management and UPS
control within the network (even internet) is
presented .
The UPSilon 2000 soft ware has coincidence and
arrangement ability with operational systems of
windows 95 / 98 / 2000 / ME /NT/XP Linux , Novell ,
unix and etc , is able to display parameters such as
: voltage , frequency , loading limit , condition of
battery , foult registration , reports and the UPS
condition and ect , and when the battery energy is
finished , the computes files are saved and the Ato
Shut Down operates .
Some other advantage of using communication tools
are as followings :
* Information saves and turning off the apparatus
while UPS battery is going to be discharged
completely .
* Contact with specific person through mobile phone
, fixed telephone , pager , E-mail and … ect , when
necessary .
* Display voltage and frequency in input and output
, battery condition and loading condition .
* Display the UPS operation report , registration
and savings of the hinds and the correct time of
faults .
* Ability of programming for UPS turning an and off
and etc .
UPS output
The complete sinuos wave shape in UPS output
protects the very sensitive apparatus against the
problems of local electricity .
Power surge : increasing sudden voltage
Increasing the limites of voltage (Usually more than
110%) of local electricity for a much cycls
frequently , this increasings come after lessening
the loads , or turning off a large loading .
Overvoltage : Increasing voltage for a long time
The increasing limits of local electricity voltage
for a long time . This case uaually relates to the
distribution of the local electricity network , and
can cause various different damages , for apparatues
.
Spike / Transient : Sudden hard fluctuations
These are the sudden hard fluctuations that usually
have one or two cycle duration . These fluctuation
will effect on the process operation and
transmission of information .
Frequency variation :
Frequency variation in the local city .
This case , that , is one the difficulties of
support source such as generators , can cause
problems on the operation of apparatuses .
Power failure : going off the local electricity
Power failure is the complete going off the current
electricity , for a period of time more than half a
cycle , going off the electricity can cause to miss
the information and also damage the hardware of
apparatuses .
Power Sag : Reduction of voltage momentary
Reduction of voltage limit on local electricity for
a few cycles continuously is a matter that comes
from starting to work in a large load with high
current , such as air-condition apparatuses or
electrical motors .
Under voltage : Reduction of voltage continuous
That is the reduction of voltage limit of local
electricity for a long time . This problem usually
is related to electricity distribution network , and
can cause many difficulties for apparatuses . |